Analog Output Card and Cable, Technical Data
For HP 1000 A-Series Products with 24 kHz Power
Product Number 12062A and 12062AC
Features
o 4 channels of voltage output/card
o Output range of 10.24 volts
o 12 bit resolution including sign
o Short circuit and overvoltage protection
o One undedicated digital output per channel
o 90 kHz output from memory
o Programmable data rates
Description
HP 12062A Card
The HP 12062A is a plug-in card for the HP 1000 A-Series computers
for low-cost, high-performance analog output capability in small
distributed measurement and control applications.
The HP 12062A Analog Output Card provides 4 independent bipolar
voltage outputs. Remote sensing per channel provides accurate output
voltages compensating for long distances of field wiring. Undedicated
digital outputs may be used in pen up/down control, CRT display, or X-Y
plotters.
DMA-compatibility provides fast analog updates on a per channel basis
or between channels. Programmable time delay between DMA updates
provides signal reconstruction capability with a full power bandwidth of
20 kHz.
HP 12062AC Cable
The HP 12062AC 4-Channel Analog Output Cable provides for easy
connection of your application to the HP 12062A. The HP 12062AC provides
a 3-meter cable prewired to the appropriate card-compatible
edge-connector/hood assembly. Each channel is an individually shielded
twisted pair for optimal analog performance. The "remote" end of the
cable is unterminated allowing direct wiring to the application.
Alternately, the cable may be wired to the easy-to-use insulation
displacement HP 12064A Termination Accessory providing
electrician-compatible heavy-duty screw terminals and built-in wiring
tray (see HP 12064A data sheet).
User Programming
User programming of the HP 12062A card is easily accomplished using the
parallel interface I/O driver (ID.50) in the RTE-A Operating System. A
simple RTE EXEC call in the following format is used:
Call EXEC (2, LU#, Data Buffer, #readings, control word) D
The control word specifies a time delay between successive DMA word
transfers. Each increment (up to 255) in the control word adds a 1.085
microsecond time delay to the 10.85 microsecond base rate.
Calibration
The HP 12062A is calibrated at the factory and may require recalibration
by the customer upon arrival by using a voltmeter and optional
calibration software.
Functional Specifications
HP 12062A Card
Number of Channels: 4 bipolar
Resolution: 12 bits, LSB=5mV
Voltage Output Range: -10.24 to +10.235 V at 20 mA
Short Circuit and Overvoltage Protection: Protected against short to
common or overvoltage up to +15 V dc
Accuracy
Linearity error (0 degrees C to 70 degrees C): 2.5 mV max
Monotonicity temperature range: 0 degrees C to 70 degrees C (32
degrees F to 131 degrees F)
Gain error: Adjustable to zero
Offset error: Adjustable to zero
Drift
Offset drift: 0.0015% of FSR per C, max
Gain drift: 0.0015% of FSR per C, max
Total error: (0 degrees C to 70 degrees C): 0.15% of FSR max
Output Characteristics
Slew rate: 10 V/ms, resistive load
Setting time for FSR change: 5 ms typical with resistive load
Full power bandwidth: 20 kHz with resistive load
Ripple and output noise: 2.5 mV p-p max (dc to 500 kHz, no load)
Fastest Update Time: 10.85 ohms
Programmable Times: 10.85 ohms to 288.61 ohms in increments of
1.085 ohms
Digital Outputs
TTL Level per channel: 1 Load per channel: 10 standard TTL loads
Physical Characteristics
Dimensions: 28.9 cm long by 17.2 cm wide by 1.9 cm high (11.4 in by
6.75 in by 0.75 in)
Net Weight: 0.36 kg (12.75 oz)
Power Requirements: 6.0 W at 5 V dc, 7.6 W at 25 kHz ac
HP 12062AC Cable
Physical Characteristics
Cable length: 3 m (9.84 ft)
Wire Gauge: 22
Overall Diameter: <1.31 cm (0.515 in)
Electrical Characteristics
Configuration: 9 shielded twisted pairs plus one drain per pair
Voltage rating: 300 V peak
Environmental Characteristics: (both products)
Operating Temperature: 0 degrees C to 55 degrees C (32 degrees F to
131 degrees F)
Storage Temperature: -40 degrees C to 75 degrees C (-40 degrees F to
167 degrees F)
Relative Humidity: 5% to 95% at 40 degrees C (104 degrees F)
noncondensing
Operating Altitude: to 4.6 km (15,000 ft)
Non-operating Altitude: to 15.3 km (50,000 ft)
System Compatibility: All HP 1000 A-Series computers with 25 kHz
power option. See HP 1000 Ordering Information (P/N 5953-8730).
Ordering Information
The HP 12062A includes:
12062-60011 4-channel DAC Card
12060-90003 User Information Manual
12062-90001 Operating and Service Manual
HP 12062A Options
001 Adds Edge Connector Kit and extra edge connector
020 Adds Calibration Program on minicartridge
(P/N 12062-13301)
041 Adds Calibration Program on 8-inch flexible disk
(P/N 12062-13401)
044 Adds Calibration Program on 3 1/2-inch microfloppy disk
(P/N 12062-13402)
Note: Calibration requires A-Series card extender (P/N 12011-60001)
and HP 3455A Multimeter (or equivalent).
The HP 12062AC includes:
A 3-meter unterminated cable with 9 individually shielded twisted
pairs.
Diagnostics
Diagnostics software is supplied with the HP 24612A. This product
includes diagnostic manuals, diagnostic software, and test hoods for the
A-Series Measurement and Control interfaces including the HP 12060B,
HP 12061A, HP 12062A, and the HP 12063A. Must order one of the following
media options: 020, 022, 041, 042, 044, or 051.
Related Product Information
MAC/1000 Software Library
This product provides a set of high-level call subroutines for the
A-Series M&C family. These calls make upgrades to higher point count
applications, via Control 1000, straightforward. For more information
contact:
Demand Systems, Inc.
6279 Variel Avenue, Suite D
Woodland Hills, CA 91367
Attn: Frank Zuhde
(213) 710-8851
From HP Networking Communications Specifications Guide,
5091-3821E, 9205, p 436
Associated files: none
Analog Output Card and Cable, Technical Data