home *** CD-ROM | disk | FTP | other *** search
/ Power Tools 1993 November - Disc 1 / Power Tools Plus (Disc 1 of 2)(November 1993)(HP).iso / spec / a3821436 / a3821436.txt < prev   
Text File  |  1992-05-09  |  6KB  |  152 lines

  1. Analog Output Card and Cable, Technical Data
  2.    For HP 1000 A-Series Products with 24 kHz Power
  3.    Product Number 12062A and 12062AC
  4. Features
  5. o 4 channels of voltage output/card
  6. o Output range of 10.24 volts
  7. o 12 bit resolution including sign
  8. o Short circuit and overvoltage protection
  9. o One undedicated digital output per channel
  10. o 90 kHz output from memory
  11. o Programmable data rates
  12.  
  13. Description
  14. HP 12062A Card
  15.    The HP 12062A is a plug-in card for the HP 1000 A-Series computers
  16. for low-cost, high-performance analog output capability in small
  17. distributed measurement and control applications.
  18.    The HP 12062A Analog Output Card provides 4 independent bipolar
  19. voltage outputs. Remote sensing per channel provides accurate output
  20. voltages compensating for long distances of field wiring. Undedicated
  21. digital outputs may be used in pen up/down control, CRT display, or X-Y
  22. plotters.
  23.    DMA-compatibility provides fast analog updates on a per channel basis
  24. or between channels. Programmable time delay between DMA updates
  25. provides signal reconstruction capability with a full power bandwidth of
  26. 20 kHz.
  27.    HP 12062AC Cable
  28. The HP 12062AC 4-Channel Analog Output Cable provides for easy
  29. connection of your application to the HP 12062A. The HP 12062AC provides
  30. a 3-meter cable prewired to the appropriate card-compatible
  31. edge-connector/hood assembly. Each channel is an individually shielded
  32. twisted pair for optimal analog performance. The "remote" end of the
  33. cable is unterminated allowing direct wiring to the application.
  34. Alternately, the cable may be wired to the easy-to-use insulation
  35. displacement HP 12064A Termination Accessory providing
  36. electrician-compatible heavy-duty screw terminals and built-in wiring
  37. tray (see HP 12064A data sheet).
  38.    User Programming
  39. User programming of the HP 12062A card is easily accomplished using the
  40. parallel interface I/O driver (ID.50) in the RTE-A Operating System. A
  41. simple RTE EXEC call in the following format is used:
  42.  
  43. Call EXEC (2, LU#, Data Buffer, #readings, control word) D
  44.  
  45. The control word specifies a time delay between successive DMA word
  46. transfers. Each increment (up to 255) in the control word adds a 1.085
  47. microsecond time delay to the 10.85 microsecond base rate.
  48.    Calibration
  49. The HP 12062A is calibrated at the factory and may require recalibration
  50. by the customer upon arrival by using a voltmeter and optional
  51. calibration software.
  52.  
  53. Functional Specifications
  54. HP 12062A Card
  55.    Number of Channels:  4 bipolar
  56.    Resolution:  12 bits, LSB=5mV
  57.    Voltage Output Range:  -10.24 to +10.235 V at 20 mA
  58.    Short Circuit and Overvoltage Protection:  Protected against short to
  59.       common or overvoltage up to +15 V dc
  60.    Accuracy
  61.       Linearity error (0 degrees C to 70 degrees C):  2.5 mV max
  62.       Monotonicity temperature range:  0 degrees C to 70 degrees C (32
  63.          degrees F to 131 degrees F)
  64.       Gain error:  Adjustable to zero
  65.       Offset error:  Adjustable to zero
  66.    Drift
  67.       Offset drift:  0.0015% of FSR per C, max
  68.       Gain drift:  0.0015% of FSR per C, max
  69.       Total error:  (0 degrees C to 70 degrees C):  0.15% of FSR max
  70.    Output Characteristics
  71.       Slew rate:  10 V/ms, resistive load
  72.       Setting time for FSR change:  5 ms typical with resistive load
  73.       Full power bandwidth:  20 kHz with resistive load
  74.       Ripple and output noise:  2.5 mV p-p max (dc to 500 kHz, no load)
  75.       Fastest Update Time:  10.85 ohms
  76.       Programmable Times:  10.85 ohms to 288.61 ohms in increments of
  77.          1.085 ohms
  78.    Digital Outputs
  79.       TTL Level per channel:  1 Load per channel:  10 standard TTL loads
  80.  
  81. Physical Characteristics
  82.    Dimensions:  28.9 cm long by 17.2 cm wide by 1.9 cm high (11.4 in by
  83.       6.75 in by 0.75 in)
  84.    Net Weight:  0.36 kg (12.75 oz)
  85.    Power Requirements:  6.0 W at 5 V dc, 7.6 W at 25 kHz ac
  86.  
  87. HP 12062AC Cable
  88.    Physical Characteristics
  89.       Cable length:  3 m (9.84 ft)
  90.       Wire Gauge:  22
  91.       Overall Diameter:  <1.31 cm (0.515 in)
  92.  
  93. Electrical Characteristics
  94.    Configuration:  9 shielded twisted pairs plus one drain per pair
  95.    Voltage rating:  300 V peak
  96.  
  97. Environmental Characteristics:  (both products)
  98.    Operating Temperature:  0 degrees C to 55 degrees C (32 degrees F to
  99.       131 degrees F)
  100.    Storage Temperature:  -40 degrees C to 75 degrees C (-40 degrees F to
  101.       167 degrees F)
  102.    Relative Humidity:  5% to 95% at 40 degrees C (104 degrees F)
  103.       noncondensing
  104.    Operating Altitude:  to 4.6 km (15,000 ft)
  105.    Non-operating Altitude:  to 15.3 km (50,000 ft)
  106.    System Compatibility:  All HP 1000 A-Series computers with 25 kHz
  107.       power option. See HP 1000 Ordering Information (P/N 5953-8730).
  108.  
  109. Ordering Information
  110. The HP 12062A includes:
  111.    12062-60011 4-channel DAC Card
  112.    12060-90003 User Information Manual
  113.    12062-90001 Operating and Service Manual
  114.       HP 12062A Options
  115.          001   Adds Edge Connector Kit and extra edge connector
  116.          020   Adds Calibration Program on minicartridge
  117.                (P/N 12062-13301)
  118.          041   Adds Calibration Program on 8-inch flexible disk
  119.                (P/N 12062-13401)
  120.          044   Adds Calibration Program on 3 1/2-inch microfloppy disk
  121.                (P/N 12062-13402)
  122.    Note:  Calibration requires A-Series card extender (P/N 12011-60001)
  123. and HP 3455A Multimeter (or equivalent).
  124.    The HP 12062AC includes:
  125.       A 3-meter unterminated cable with 9 individually shielded twisted
  126.       pairs.
  127.  
  128. Diagnostics
  129. Diagnostics software is supplied with the HP 24612A. This product
  130. includes diagnostic manuals, diagnostic software, and test hoods for the
  131. A-Series Measurement and Control interfaces including the HP 12060B,
  132. HP 12061A, HP 12062A, and the HP 12063A. Must order one of the following
  133. media options:  020, 022, 041, 042, 044, or 051.
  134.  
  135. Related Product Information
  136. MAC/1000 Software Library
  137.    This product provides a set of high-level call subroutines for the
  138. A-Series M&C family. These calls make upgrades to higher point count
  139. applications, via Control 1000, straightforward. For more information
  140. contact:
  141.       Demand Systems, Inc.
  142.       6279 Variel Avenue, Suite D
  143.       Woodland Hills, CA 91367
  144.       Attn:  Frank Zuhde
  145.       (213) 710-8851
  146.  
  147.  
  148. From HP Networking Communications Specifications Guide,
  149.    5091-3821E, 9205, p 436
  150. Associated files:  none
  151. Analog Output Card and Cable, Technical Data
  152.